Material Precautions
- Keep adhesives and cleaning products away from ignition sources such as torches, flames, fire, sparks, etc. Do not smoke in the vicinity of these products. Store and use these products in well-ventilated areas.
- Keep products stored in a cool, dry place, away from direct sunlight.
- Mix the adhesives and primers before and during installation. Bring them to room temperature before use if they have been exposed to temperatures lower than 10°c.
- Particular attention must be paid to adhesives and primers during hot weather. High temperatures can cause solvents to evaporate quickly. This can be avoided by protecting the materials by placing an insulation board underneath them and covering them with an offcut of EPDM membrane on particularly hot days.
- Never use a torch or hot air gun to speed up drying times of adhesives or primers. Only natural drying is permitted.
- Protect the RubberCover EPDM membrane from any contact with hydrocarbons (fuel, gasoline, diesel etc) mineral and vegetable oils, organic-based solvents, grease, animal fats and fresh bitumen (less than 4 weeks old). Do not use damaged materials that do not allow optimal use.
- Do not allow the RubberCover EPDM membrane or its accessories to come in to contact with steam or any heat source above 80°C.
- Fumes from adhesives and Primers may penetrate into the building during installation through air intake openings in the roof. Please take the appropriate measures to avoid this.